@@ -1,53 +1,62 @@
|
|
|
|
|
=====================================
|
|
|
|
|
Dell EMC ScaleIO Block Storage driver
|
|
|
|
|
=====================================
|
|
|
|
|
===========================================
|
|
|
|
|
Dell EMC VxFlex OS (ScaleIO) Storage driver
|
|
|
|
|
===========================================
|
|
|
|
|
|
|
|
|
|
Overview
|
|
|
|
|
--------
|
|
|
|
|
|
|
|
|
|
ScaleIO is a software-only solution that uses existing servers' local
|
|
|
|
|
Dell EMC VxFlex OS (formerly named Dell EMC ScaleIO) is a software-only
|
|
|
|
|
solution that uses existing servers local
|
|
|
|
|
disks and LAN to create a virtual SAN that has all of the benefits of
|
|
|
|
|
external storage, but at a fraction of the cost and complexity. Using the
|
|
|
|
|
driver, Block Storage hosts can connect to a ScaleIO Storage
|
|
|
|
|
driver, Block Storage hosts can connect to a VxFlex OS Storage
|
|
|
|
|
cluster.
|
|
|
|
|
|
|
|
|
|
.. _scale_io_docs:
|
|
|
|
|
The Dell EMC VxFlex OS Cinder driver is designed and tested to work with
|
|
|
|
|
both VxFlex OS and with ScaleIO. The
|
|
|
|
|
:ref:`configuration options <cg_configuration_options_emc>`
|
|
|
|
|
are identical for both VxFlex OS and ScaleIO.
|
|
|
|
|
|
|
|
|
|
Official ScaleIO documentation
|
|
|
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
|
.. _scaleio_docs:
|
|
|
|
|
|
|
|
|
|
To find the ScaleIO documentation:
|
|
|
|
|
Official VxFlex OS documentation
|
|
|
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
|
|
|
|
|
|
#. Go to the `ScaleIO product documentation page <https://support.emc.com/products/33925_ScaleIO/Documentation/?source=promotion>`_.
|
|
|
|
|
To find the VxFlex OS documentation:
|
|
|
|
|
|
|
|
|
|
#. From the left-side panel, select the relevant ScaleIO version.
|
|
|
|
|
#. Go to the `VxFlex OS product documentation page <https://support.emc.com/products/33925_ScaleIO/Documentation/?source=promotion>`_.
|
|
|
|
|
|
|
|
|
|
Supported ScaleIO Versions
|
|
|
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
|
#. From the left-side panel, select the relevant VxFlex OS version.
|
|
|
|
|
|
|
|
|
|
The Dell EMC ScaleIO Block Storage driver has been tested against the
|
|
|
|
|
following versions of ScaleIO and found to be compatible:
|
|
|
|
|
Supported VxFlex OS and ScaleIO Versions
|
|
|
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
|
|
|
|
|
|
The Dell EMC VxFlex OS Block Storage driver has been tested against the
|
|
|
|
|
following versions of ScaleIO and VxFlex OS and found to be compatible:
|
|
|
|
|
|
|
|
|
|
* ScaleIO 2.0.x
|
|
|
|
|
* ScaleIO 2.5.x
|
|
|
|
|
* VxFlex OS 2.6.x
|
|
|
|
|
|
|
|
|
|
Please consult the :ref:`scale_io_docs`
|
|
|
|
|
to determine supported operating systems for each version of ScaleIO.
|
|
|
|
|
Please consult the :ref:`scaleio_docs`
|
|
|
|
|
to determine supported operating systems for each version
|
|
|
|
|
of VxFlex OS or ScaleIO.
|
|
|
|
|
|
|
|
|
|
Deployment prerequisites
|
|
|
|
|
~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
|
|
|
|
|
|
* ScaleIO Gateway must be installed and accessible in the network.
|
|
|
|
|
* The VxFlex OS Gateway must be installed and accessible in the network.
|
|
|
|
|
For installation steps, refer to the Preparing the installation Manager
|
|
|
|
|
and the Gateway section in ScaleIO Deployment Guide. See
|
|
|
|
|
:ref:`scale_io_docs`.
|
|
|
|
|
and the Gateway section in VxFlex OS Deployment Guide. See
|
|
|
|
|
:ref:`scaleio_docs`.
|
|
|
|
|
|
|
|
|
|
* ScaleIO Data Client (SDC) must be installed on all OpenStack nodes.
|
|
|
|
|
* VxFlex OS Storage Data Client (SDC) must be installed
|
|
|
|
|
on all OpenStack nodes.
|
|
|
|
|
|
|
|
|
|
.. note:: Ubuntu users must follow the specific instructions in the ScaleIO
|
|
|
|
|
Deployment Guide for Ubuntu environments. See the ``Deploying on
|
|
|
|
|
Ubuntu Servers`` section in ScaleIO Deployment Guide. See
|
|
|
|
|
:ref:`scale_io_docs`.
|
|
|
|
|
.. note:: Ubuntu users must follow the specific instructions in the VxFlex
|
|
|
|
|
OS Deployment Guide for Ubuntu environments. See the ``Deploying
|
|
|
|
|
on Ubuntu Servers`` section in VxFlex OS Deployment Guide. See
|
|
|
|
|
:ref:`scaleio_docs`.
|
|
|
|
|
|
|
|
|
|
Supported operations
|
|
|
|
|
~~~~~~~~~~~~~~~~~~~~
|
|
|
|
@@ -71,11 +80,11 @@ Supported operations
|
|
|
|
|
* Create, list, update, and delete consistency group snapshots
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ScaleIO Block Storage driver configuration
|
|
|
|
|
------------------------------------------
|
|
|
|
|
VxFlex OS Block Storage driver configuration
|
|
|
|
|
--------------------------------------------
|
|
|
|
|
|
|
|
|
|
This section explains how to configure and connect the block storage
|
|
|
|
|
nodes to a ScaleIO storage cluster.
|
|
|
|
|
nodes to a VxFlex OS storage cluster.
|
|
|
|
|
|
|
|
|
|
Edit the ``cinder.conf`` file by adding the configuration below under
|
|
|
|
|
a new section (for example, ``[scaleio]``) and change the ``enable_backends``
|
|
|
|
@@ -86,8 +95,8 @@ The configuration file is usually located at
|
|
|
|
|
For a configuration example, refer to the example
|
|
|
|
|
:ref:`cinder.conf <cg_configuration_example_emc>` .
|
|
|
|
|
|
|
|
|
|
ScaleIO driver name
|
|
|
|
|
~~~~~~~~~~~~~~~~~~~
|
|
|
|
|
VxFlex OS driver name
|
|
|
|
|
~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
|
|
|
|
|
|
Configure the driver name by adding the following parameter:
|
|
|
|
|
|
|
|
|
@@ -95,19 +104,19 @@ Configure the driver name by adding the following parameter:
|
|
|
|
|
|
|
|
|
|
volume_driver = cinder.volume.drivers.dell_emc.scaleio.driver.ScaleIODriver
|
|
|
|
|
|
|
|
|
|
ScaleIO Gateway server IP
|
|
|
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
|
VxFlex OS Gateway server IP
|
|
|
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
|
|
|
|
|
|
The ScaleIO Gateway provides a REST interface to ScaleIO.
|
|
|
|
|
The VxFlex OS Gateway provides a REST interface to VxFlex OS.
|
|
|
|
|
|
|
|
|
|
Configure the Gateway server IP address by adding the following parameter:
|
|
|
|
|
|
|
|
|
|
.. code-block:: ini
|
|
|
|
|
|
|
|
|
|
san_ip = <ScaleIO GATEWAY IP>
|
|
|
|
|
san_ip = <VxFlex OS GATEWAY IP>
|
|
|
|
|
|
|
|
|
|
ScaleIO Storage Pools
|
|
|
|
|
~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
|
VxFlex OS Storage Pools
|
|
|
|
|
~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
|
|
|
|
|
|
Multiple Storage Pools and Protection Domains can be listed for use by
|
|
|
|
|
the virtual machines. The list should include every Protection Domain and
|
|
|
|
@@ -122,14 +131,14 @@ Configure the available Storage Pools by adding the following parameter:
|
|
|
|
|
|
|
|
|
|
sio_storage_pools = <Comma-separated list of protection domain:storage pool name>
|
|
|
|
|
|
|
|
|
|
ScaleIO user credentials
|
|
|
|
|
~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
|
VxFlex OS user credentials
|
|
|
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
|
|
|
|
|
|
Block Storage requires a ScaleIO user with administrative
|
|
|
|
|
privileges. ScaleIO recommends creating a dedicated OpenStack user
|
|
|
|
|
Block Storage requires a VxFlex OS user with administrative
|
|
|
|
|
privileges. Dell EMC recommends creating a dedicated OpenStack user
|
|
|
|
|
account that has an administrative user role.
|
|
|
|
|
|
|
|
|
|
Refer to the ScaleIO User Guide for details on user account management.
|
|
|
|
|
Refer to the VxFlex OS User Guide for details on user account management.
|
|
|
|
|
|
|
|
|
|
Configure the user credentials by adding the following parameters:
|
|
|
|
|
|
|
|
|
@@ -142,7 +151,7 @@ Oversubscription
|
|
|
|
|
~~~~~~~~~~~~~~~~
|
|
|
|
|
|
|
|
|
|
Configure the oversubscription ratio by adding the following parameter
|
|
|
|
|
under the separate section for ScaleIO:
|
|
|
|
|
under the separate section for VxFlex OS:
|
|
|
|
|
|
|
|
|
|
.. code-block:: ini
|
|
|
|
|
|
|
|
|
@@ -156,7 +165,7 @@ under the separate section for ScaleIO:
|
|
|
|
|
Oversubscription is calculated correctly by the Block Storage service
|
|
|
|
|
only if the extra specification ``provisioning:type``
|
|
|
|
|
appears in the volume type regardless of the default provisioning type.
|
|
|
|
|
Maximum oversubscription value supported for ScaleIO is 10.0.
|
|
|
|
|
Maximum oversubscription value supported for VxFlex OS is 10.0.
|
|
|
|
|
|
|
|
|
|
Default provisioning type
|
|
|
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
@@ -202,10 +211,12 @@ parameters as follows:
|
|
|
|
|
san_password = SIO_PASSWD
|
|
|
|
|
san_thin_provision = false
|
|
|
|
|
|
|
|
|
|
.. _cg_configuration_options_emc:
|
|
|
|
|
|
|
|
|
|
Configuration options
|
|
|
|
|
~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
|
|
|
|
|
|
The ScaleIO driver supports these configuration options:
|
|
|
|
|
The VxFlex OS driver supports these configuration options:
|
|
|
|
|
|
|
|
|
|
.. config-table::
|
|
|
|
|
:config-target: ScaleIO
|
|
|
|
@@ -216,11 +227,11 @@ Volume Types
|
|
|
|
|
------------
|
|
|
|
|
|
|
|
|
|
Volume types can be used to specify characteristics of volumes allocated via the
|
|
|
|
|
ScaleIO Driver. These characteristics are defined as ``Extra Specs`` within
|
|
|
|
|
VxFlex OS Driver. These characteristics are defined as ``Extra Specs`` within
|
|
|
|
|
``Volume Types``.
|
|
|
|
|
|
|
|
|
|
ScaleIO Protection Domain and Storage Pool
|
|
|
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
|
VxFlex OS Protection Domain and Storage Pool
|
|
|
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
|
|
|
|
|
|
When multiple storage pools are specified in the Cinder configuration,
|
|
|
|
|
users can specify which pool should be utilized by adding the ``pool``
|
|
|
|
@@ -233,8 +244,8 @@ requested protection_domain:storage_pool.
|
|
|
|
|
$ openstack volume type set --property volume_backend_name=scaleio sio_type_1
|
|
|
|
|
$ openstack volume type set --property pool=Domain2:Pool2 sio_type_1
|
|
|
|
|
|
|
|
|
|
ScaleIO thin provisioning support
|
|
|
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
|
VxFlex OS thin provisioning support
|
|
|
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
|
|
|
|
|
|
The Block Storage driver supports creation of thin-provisioned and
|
|
|
|
|
thick-provisioned volumes.
|
|
|
|
@@ -246,10 +257,10 @@ of the volume type, as follows:
|
|
|
|
|
$ openstack volume type create sio_type_thick
|
|
|
|
|
$ openstack volume type set --property provisioning:type=thick sio_type_thick
|
|
|
|
|
|
|
|
|
|
ScaleIO QoS support
|
|
|
|
|
~~~~~~~~~~~~~~~~~~~
|
|
|
|
|
VxFlex OS QoS support
|
|
|
|
|
~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
|
|
|
|
|
|
QoS support for the ScaleIO driver includes the ability to set the
|
|
|
|
|
QoS support for the VxFlex OS driver includes the ability to set the
|
|
|
|
|
following capabilities:
|
|
|
|
|
|
|
|
|
|
``maxIOPS``
|
|
|
|
@@ -287,8 +298,8 @@ and the relevant calculated value of ``maxIOPSperGB`` or ``maxBWSperGB``.
|
|
|
|
|
Since the limits are per SDC, they will be applied after the volume
|
|
|
|
|
is attached to an instance, and thus to a compute node/SDC.
|
|
|
|
|
|
|
|
|
|
Using ScaleIO Storage with a containerized overcloud
|
|
|
|
|
----------------------------------------------------
|
|
|
|
|
Using VxFlex OS Storage with a containerized overcloud
|
|
|
|
|
------------------------------------------------------
|
|
|
|
|
|
|
|
|
|
When using a containerized overcloud, such as one deployed via TripleO or RedHat
|
|
|
|
|
Openstack version 12 and above, there is an additional step that must be
|
|
|
|
@@ -297,7 +308,7 @@ performed.
|
|
|
|
|
Before deploying the overcloud
|
|
|
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
|
|
|
|
|
|
After ensuring that the ScaleIO Data Client (SDC) is installed on all nodes and
|
|
|
|
|
After ensuring that the Storage Data Client (SDC) is installed on all nodes and
|
|
|
|
|
before deploying the overcloud,
|
|
|
|
|
modify the TripleO Heat Template for the nova-compute and cinder-volume
|
|
|
|
|
containers to add volume mappings for directories containing the SDC
|